> Has anybody found/thought of an ingenious method of properly
tensioning guy wires (3/16 EHS) without the tension guages?
> I've seen the vibration/resonance/harmonic method, but to do it
properly requires that the wires are already properly tensioned and
that you find the first harmonic to use as a baseline in future checks.
Yes, that is the only other method. And it's for big, long guy wires - not
35' of EHS.
> Tower standing to 30ft, anchors down, guy wires hanging, come-alongs and
cable
grips on the deck. just gotta figure out how to do this properly
(nobody around here rents the tension guages).
The guys shouldn't be slack and they shouldn't be bar tight. For 30' of
tower, it's kind of hard to screw up the tension. The recommended tension is
400# which is a bunch so tighten the turnbuckles until there's 6-8" of
movement in the guys when you really wiggle them and that'll probably be close
enough.
Cheers & GL,
Steve K7LXC