Towertalk
[Top] [All Lists]

Re: [TowerTalk] bracketed 45G

To: jimjarvis@optonline.net, bobbrus1@netscape.net,towertalk@contesting.com
Subject: Re: [TowerTalk] bracketed 45G
From: bobbrus1@netscape.net
Date: Wed, 04 Apr 2007 19:52:13 -0400
List-post: <mailto:towertalk@contesting.com>
Thanks for the response Jim.

I have a full two story with a walk up attic so I have access to put a load 
distribution system in place.  My current plan is to build heavy duty steel 
brackets that distribute the load across both the roof and floor system in the 
attic area.   I believe this will answer part of your (and my) concerns to 
ensure the bracket used from the tower to the house will be able to take the 
load.

Another question I would ask about putting one set of guys up....can the guy 
wires be tied into the roof system assuming a significant bracket mounted into 
the roof rafter?

Thanks again


Bob
 
 
-----Original Message-----
From: jimjarvis@optonline.net
To: bobbrus1@netscape.net; towertalk@contesting.com
Sent: Wed, 4 Apr 2007 8:09 AM
Subject: bracketed 45G



Bob,

The Rohn catalog/handbook detail for a bracketed antenna
doesn't tell the whole story.

At my old place in VT, I had 50' of 45G house bracketed,
with a T8 log periodic and an R7000 vertical on top.  The system
was bracketed into the roof truss system of a flat-roof house,
as well as the floor-truss system.  i.e. two brackets, one at
6', the other at 16'.  

Both truss systems were made of 2x12's, due to snow-load
considerations.  The lateral load capability of the system,
per architect's calculations, was 3x what the tower was
capable of imposing, with the highest winds ever recorded
in the area.  

That said, you need to know what the house will stand, before
you apply a point-load on it.  Or, you need to plan for
a structural distribution of the load, within the roof system.  

In my case, I had no more than 10sf on top, including the 10' 
mast.  Dave, K4JRB's point about the th11 is a good one.  I wouldn't
be comfortable with it above 40', unless I had numbers to base that
decision upon.  One set of guys will make a huge difference.  

N2EA
Jim Jarvis, President
The Morse Group, LLC
We create high-performance organizations.
732 548 5573 office
443 618 5560 cell
jimjarvis@themorsegroup.net
www.themorsegroup.net 
________________________________________________________________________
Check Out the new free AIM(R) Mail -- 2 GB of storage and industry-leading spam 
and email virus protection.
_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>