Subject: Re: [TowerTalk] Subject: Re: Managing Balanced line transitions through the core".
Consider two wires passing through a ferrite core. If they carry ideal balanced currents,
one current will induce a field in the core and the other current will induce a field in
the core that is 180 degrees out of phase with the first one. Thus, zero flux will exist
in that core under ideal conditions.

I wasn't very clear here. The only argument I am presenting is whether to install a 1:1 current-choke-balun at a balanced to unbalanced junction where the impedance is unknown and the amount of unbalance is unknown. It is not only good engineering practice to install the 1:1 current-choke-balun but also to choose a design where the differential transmission line currents do not induce appreciable flux in the ferrite. A 1:1 current-choke-balun can indeed simultaneously perform the choking function and the balun function. That's how a W2DU balun works and W8JI recommends 1:1 current-choke-baluns in applications where the impedances are unknown.
--
73, Cecil, w5dxp.com


_________________________________________________________________
Valentine?s Day -- Shop for gifts that spell L-O-V-E at MSN Shopping http://shopping.msn.com/content/shp/?ctId=8323,ptnrid=37,ptnrdata=24095&tcode=wlmtagline


_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
<Prev in Thread] Current Thread [Next in Thread>