To: | towertalk@contesting.com |
---|---|
Subject: | [TowerTalk] Ground radials to ufer ground connection |
From: | kb9cry@comcast.net (Phil Camera) |
Date: | Wed, 13 Dec 2006 15:53:33 +0000 |
List-post: | <mailto:towertalk@contesting.com> |
No need for a separate down conductor. The tower is metal and can handle the surge energy. I can't comment on the ufer connection but you'll also want to have separate ground radials connected to each tower leg. Polyphaser recommends 50 - 75 feet long radials with ground rods located every 2X rod height. Phil KB9CRY _______________________________________________ _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk |