Towertalk
[Top] [All Lists]

Re: [TowerTalk] Radials - bare or insulated?

To: "Jim Miller" <JimMiller@STL-OnLine.Net>,"TOWERTALK Reflector" <TOWERTALK@contesting.com>
Subject: Re: [TowerTalk] Radials - bare or insulated?
From: Jim Lux <jimlux@earthlink.net>
Date: Tue, 22 Aug 2006 06:46:51 -0700
List-post: <mailto:towertalk@contesting.com>
At 02:57 AM 8/22/2006, Jim Miller wrote:
>Is there an advantage to using bare radial wires vs. insulated to get 
>electrical contact with earth?  I used insulated 22 gauge wire (1000 ft) 
>for radials around my vertical thinking it would last longer than bare 
>wire.  Now I wonder if I hurt the performance.


I would think not.  You're concerned about RF currents, and the dielectric 
around the wire just makes it look like a series capacitor (but one of very 
low impedance) to the surrounding soil.



_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk