Towertalk
[Top] [All Lists]

Re: [TowerTalk] Grounding base slab and pier tower bases

To: towertalk@contesting.com
Subject: Re: [TowerTalk] Grounding base slab and pier tower bases
From: Doug Renwick <ve5ra@sasktel.net>
Date: Tue, 04 Jul 2006 08:06:37 -0600
List-post: <mailto:towertalk@contesting.com>
Not true in my case.  Before I installed the porcupine my
mast bleed off the charge.  A number of years ago I added
the porcupine and my mast/porcupine combo still bleeds off
the charge.  In other words, my addition of the porcupine
did not have a negative effect.  In almost 30 years I have
not had any lightning damage.  One of my mottos is
'experience trumps theory EVERY time' and this is another
example.

Doug/VA5DX

Subject: Re: [TowerTalk] Grounding base slab and pier tower
bases

If you want to minimize the chance of a lightning strike to
your tower do
not place a device on the top with sharp points. A blunt
point rod should be
placed at the top.

The so called lightning preventers or porcupine items do
nothing to abate a
strike. In fact they can increase the chance of a lightning
strike by
providing sharp points where early streamers can form. There
is no way to
"bleed off" any energy from a tower as the earth can
re-supply it many times
faster than you can get rid of it.


73
Gary K4FMX



-- 
No virus found in this outgoing message.
Checked by AVG Free Edition.
Version: 7.1.394 / Virus Database: 268.9.8/380 - Release
Date: 6/30/2006
 