I was always taught to hop out of the field with both feet tightly together,
hitting the ground simultaneously, thus no electrical difference between
them.
73, Carl VE9OV
----- Original Message -----
From: "Jim Jarvis" <jimjarvis@verizon.net>
To: <towertalk@contesting.com>
Sent: Monday, June 26, 2006 5:27 PM
Subject: [TowerTalk] DO *NOT* WORK ON ANTENNAS During Rain
>
> Dear TT:
>
> The voltage gradient in a broadcast antenna ground field,
> in the event of a direct strike has been modelled, and
> confirmed by measurement as 1,000v/m. This was reported
> in BroadcastEngineering, as long ago as 1970.
>
> My instructions to engineering staff in event of a squall
> while within the antenna field was to HOP, or maybe to run,
> making certain that two feet never hit the ground at the same time.
> They all laughed.
>
> We had opportunity to test it. The one guy who DID allow two feet
> to hit the ground simultaneously was 190' out, at the edge of the
> radial field, from a 190' tower. He was treated for third degree
> burns in both feet, which were maybe .7 meter apart.
>
> Another time, while in college, I worked in local TV, and used to observe
> lightning
> hit a water tower, 1/4 mile from the studio building. Hearing arcs on our
> CB antenna feeder, I put a DVM across the coax. 1200V spikes were
> recorded on an analog meter, coincident with each strike. The one turn
> transformer
> effect should not be underestimated. If you're the secondary, it could be
> shocking.
>
> Jim/N2EA
>
>
>
>
>
> _______________________________________________
>
>
>
> _______________________________________________
> TowerTalk mailing list
> TowerTalk@contesting.com
> http://lists.contesting.com/mailman/listinfo/towertalk
>
>
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
|