To: | "towertalk@contesting.com" <towertalk@contesting.com> |
---|---|
Subject: | Re: [TowerTalk] New shack on the 2nd floor grounding issues |
From: | "Jim Brown" <jim@audiosystemsgroup.com> |
Reply-to: | Jim Brown <jim@audiosystemsgroup.com> |
Date: | Mon, 01 May 2006 08:01:59 -0500 |
List-post: | <mailto:towertalk@contesting.com> |
Yes, but as frequency increases, this technique begins to fall apart, thanks to the capacitance between the shield and the interior conductor. Jim K9YC --Original Message Text--- From: Peter Chadwick Date: Mon, 1 May 2006 14:55:37 +0200 (CEST) Noise pick up on long ground leads can be reduced by shielding them. This is a well known technique in professional EMC (and electronic security - TEMPEST) circles. The shield is connected to ground and inner at the ground point: the 'top' end has the shield floating.. 73 Peter G3RZP _______________________________________________ _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: [TowerTalk] New shack on the 2nd floor grounding issues, Peter Chadwick |
---|---|
Next by Date: | Re: [TowerTalk] New shack on the 2nd floor grounding issues, K4SAV |
Previous by Thread: | Re: [TowerTalk] New shack on the 2nd floor grounding issues, Peter Chadwick |
Next by Thread: | Re: [TowerTalk] New shack on the 2nd floor grounding issues, K4SAV |
Indexes: | [Date] [Thread] [Top] [All Lists] |