Towertalk
[Top] [All Lists]

Re: [TowerTalk] HyGain Crankup Tower HELP

To: <towertalk@contesting.com>
Subject: Re: [TowerTalk] HyGain Crankup Tower HELP
From: "Doug Rehman" <rehman@surveil.com>
Date: Sat, 1 Apr 2006 19:32:40 -0500
List-post: <mailto:towertalk@contesting.com>
> McMaster Carr has sheaves.  You can get them with bronze or 
> even sealed ball bearings.  For the 1/4" cable, they are only 
> 2" diameter however.

I would be very concerned about using 2" diameter sheaves for 1/4" wire
rope. It's been a little while since I researched it, but I believe the
minimum recommended size is around 4.5" or 5" for 1/4" wire rope.

There is an email in the archives
(http://lists.contesting.com/pipermail/towertalk/1998-January/011959.html)
where someone replaced 3/16" wire rope on a crank-up with 1/4" wire rope.
The 1/4" wire rope failed prematurely (after a year or two). He examined the
failed wire rope in a lab and determined it had been prematurely weakened by
running over pulleys/sheaves that were too small. 

Doug
K4DDR


_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>