At 06:39 PM 3/13/2006, CubexCo@aol.com wrote:
>In a message dated 3/13/2006 6:46:44 PM Eastern Standard Time,
>towertalk-request@contesting.com writes:
> > If you're talking about the 4 way switch, it uses the scheme of positive
> > half cycles of AC to actuate one relay and negative half cycles for the
> > other relay(s), so it definitely won't work with 12VDC supply.
>============================
>Sure you can, just swap the plus and minus DC leads - reversing the polarity.
No.. you need both half cycles. If you use DC only, you get 3 states
+,0,-... If you use AC, you get all 4 possible states: 0, +, -, and +/-
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
|