I use 10' of EHS for the lower part - one end on the turnbuckle with a
thimble and a guy grip and on the other end I use a 502 insulator (cause I
had them) with a guy grip on one side for the EHS and a guy grip (from
Phillystran) on the other side for the Phillystran.
N2TK, Tony

 -----Original Message-----
From:   towertalk-bounces@contesting.com
[mailto:towertalk-bounces@contesting.com]  On Behalf Of DOUGLAS SNOWDEN
Sent:   Saturday, February 04, 2006 6:42 PM
To:     towertalk@contesting.com
Subject:        [TowerTalk] Terminating Phillystran at the ground.

I was wondering what you Phillystran people do with the lower part of your
Phillystran. Do you put steel guy at the bottom?  Are you worried about
brush fires or vandals?