Re: [TowerTalk] GUY WIRE TENSION

To: "N4BAA - JOSE CASTILLO" <n4baa@cox.net>,<towertalk@contesting.com>
Subject: Re: [TowerTalk] GUY WIRE TENSION
From: "Tom McAlee" <tom@klient.com>
Date: Sat, 30 Apr 2005 16:20:54 -0400
List-post: <mailto:towertalk@contesting.com>
I'm certainly not a professional tower installer, but I believe the tension 
depends on the guy wire used not the height of the tower.  10% of the 
breaking strength is what I've seen recommended, or about 400lbs for 3/16" 
EHS 600 lbs for 1/4" EHS.

Since the guys will expand and contract with temperature, I like to adjust 
it to the correct tension when the temperature outside is about the average 
year-round temperature for my location.  I'm not sure what the pros 
recommend on that one.

I'm not aware of that general rule being different for rotating vs. fixed 
towers, but then again I've never worked on a rotating tower.

Tom, NI1N


----- Original Message ----- 
From: "N4BAA - JOSE CASTILLO" <n4baa@cox.net>
To: <towertalk@contesting.com>
Sent: Saturday, April 30, 2005 3:43 PM
Subject: [TowerTalk] GUY WIRE TENSION


> Looking for numbers for tension for 60 foot 25G guyed and
> 100 foot 45G guyed tower vs 120 foot 45G rotating tower.
> Can someone give me some figures?
>
> Thanks!
> Jose - N4BAA


_______________________________________________

See: http://www.mscomputer.com  for "Self Supporting Towers", "Wireless Weather 
Stations", and lot's more.  Call Toll Free, 1-800-333-9041 with any questions 
and ask for Sherman, W2FLA.

_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>