To: | jimjarvis@comcast.net |
---|---|
Subject: | Re: [TowerTalk] concrete and lightning |
From: | Gary Schafer <garyschafer@comcast.net> |
Reply-to: | garyschafer@comcast.net |
Date: | Thu, 27 Jan 2005 11:50:49 -0500 |
List-post: | <mailto:towertalk@contesting.com> |
jimjarvis@comcast.net wrote: I was responsible for a 500' self supported installation, If you don't want any strike energy to go through the concrete base then you better not have any J bolts in the concrete attached to the tower. :>) Part of the energy is going to go through the concrete whether you like it or not. The trick is to have other adequate grounding in addition to the concrete. 73 Gary K4FMX _______________________________________________ See: http://www.mscomputer.com for "Self Supporting Towers", "Wireless Weather Stations", and lot's more. Call Toll Free, 1-800-333-9041 with any questions and ask for Sherman, W2FLA. _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: [TowerTalk] Conductive Concrete and Grounding, Tom Rauch |
---|---|
Next by Date: | Re: [TowerTalk] Conductive Concrete and Grounding, K8RI on Tower Talk |
Previous by Thread: | Re: [TowerTalk] concrete and lightning, Jim Lux |
Next by Thread: | [TowerTalk] Utility pole beam mount - thanks, Randy Frazer |
Indexes: | [Date] [Thread] [Top] [All Lists] |