Towertalk
[Top] [All Lists]

RE: [TowerTalk] Conductive Concrete and Grounding

To: "'Tower Talk List'" <towertalk@contesting.com>
Subject: RE: [TowerTalk] Conductive Concrete and Grounding
From: "D. Scott MacKenzie" <kb0fhp@comcast.net>
Reply-to: kb0fhp@comcast.net
Date: Wed, 26 Jan 2005 23:24:02 -0500
List-post: <mailto:towertalk@contesting.com>
I have been hit by lightening too on my HDBX 50 tower - No damage to tower,
concrete or antennas.  Took out phone line (underground) when came down
tower, out three ground rods and 00 wire tying all together and tower, then
arcing underground to phone line.  Came in house and took out cordless phone
and a computer modem.  Better than the first time when it came down coax
from a G5RV up in a couple of trees and burned a hole in new carpet....I was
in dog house for years.......

-----Original Message-----
From: towertalk-bounces@contesting.com
[mailto:towertalk-bounces@contesting.com]On Behalf Of Keith Dutson
Sent: Wednesday, January 26, 2005 11:20 PM
To: 'Tower Talk List'
Subject: RE: [TowerTalk] Conductive Concrete and Grounding


>three sets of two guys

Did you mean two sets of three guys?

Yes, lightning can easily flash over insulators.  And yes, not grounding the
guy anchors put a huge potential across the concrete.

But, take heart as there are probably many other hams out there with less
than safe tower installations.  I admit I am one who suffered a similar
malady in my younger years.  I constructed a 70 foot tower (my own design)
and held it up with guys tied to existing trees.  When a storm passed
through the trees bent over and let the wires loose resulting in a twisted,
bent over mess that landed on the garage with the antenna barely missing the
car parked in the driveway.

Keith NM5G

-----Original Message-----
From: towertalk-bounces@contesting.com
[mailto:towertalk-bounces@contesting.com] On Behalf Of Bill Shell
Sent: Wednesday, January 26, 2005 7:36 PM
To: Tower Talk List
Subject: Re: [TowerTalk] Conductive Concrete and Grounding

In 1966, I lost a tower to a lightning strike.  The tower was a 50ft Rohn 25
with three sets of two guys.  The tower was grounded an the base with ground
rods and heavy guage wire going up about 3-4 ft where it attached to the
tower legs.  Unfortunately, the strike went down one of the guys, over or
through the heavy-duty egg insulators to the guy anchor where it cracked the
cement open.  The tower, having lost the anchor point for one set of guys,
just tipped over into my neighbors yard.

I didn't have any grounds on the guy anchor points.  I had thought there was
no need, since the guys were broken at several points with egg insulators.
I was wrong.  Lightning is too unpredictable to follow rules.

73, Bill
N6WS


_______________________________________________

See: http://www.mscomputer.com  for "Self Supporting Towers", "Wireless
Weather Stations", and lot's more.  Call Toll Free, 1-800-333-9041 with any
questions and ask for Sherman, W2FLA.

_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

_______________________________________________

See: http://www.mscomputer.com  for "Self Supporting Towers", "Wireless
Weather Stations", and lot's more.  Call Toll Free, 1-800-333-9041 with any
questions and ask for Sherman, W2FLA.

_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk


_______________________________________________

See: http://www.mscomputer.com  for "Self Supporting Towers", "Wireless Weather 
Stations", and lot's more.  Call Toll Free, 1-800-333-9041 with any questions 
and ask for Sherman, W2FLA.

_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>