----- Original Message -----
From: "W0UN -- John Brosnahan" <shr@swtexas.net>
To: <towertalk@contesting.com>
Sent: Tuesday, November 30, 2004 7:15 AM
Subject: [TowerTalk] telescoped tubing -- followup


> I received a number of responses--some on the reflector and many direct to
me.
>    ---   THANKS
>
> Just thought I would add a few comments and summarize.  BTW  I always use
an
> anti-oxidant when assembling tubing--such as Noalox.  I did not assemble
these
> tubes and I don't know if any antioxidant was used or not.
>
> In any case the tubing will be used as part of my 40M array and I have no
extra
> pieces so I need to salvage every piece if possible.  Since it is the
stronger
> 2024-T3 (and much more expensive) with a special heat treatment I want to
be
> very careful about just how hot I get it if I try to do some differential
> heating.

I have had fairly poor luck separating galled aluminum with differential
heating.  The thermal conductivity of the Al is just too high, so it all
winds up at the same temperature. However, someone had suggested to me that
heating (gently, not too hot) and cooling can help get a lubricant to move
in the gaps that aren't cold welded.  Vibration (for hours) was also
suggested. I've never tried it myself, though.

> KROIL seems to be the product recommended by the largest number of
> respondees.  Also mentioned is PB Blaster--something I have seen but never
> tried.  Think I will add a can to my stock of good tricks.  Also mentioned
was
> POMotoroil that creeps.  I'll look into it as well.
>
> So I will probably give KROIL a try first.  Some of the pipes are here in
Texas
> and some are still in Colorado.  I probably have 20 or so of these to work
on--
> so some up front effort is warranted since it will be "pro-rated" across
the
> large number of pipes to be separated.
>
>

_______________________________________________

See: http://www.mscomputer.com  for "Self Supporting Towers", "Wireless Weather 
Stations", and lot's more.  Call Toll Free, 1-800-333-9041 with any questions 
and ask for Sherman, W2FLA.

_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>