Re: [TowerTalk] Why did my Tailtwister stop turning?

To: "David Hachadorian" <K6LL@adelphia.net>,"Towertalk Reflector" <towertalk@contesting.com>
Subject: Re: [TowerTalk] Why did my Tailtwister stop turning?
From: "Brad Pioveson W9FX" <w9fx@neondsl.com>
Date: Mon, 29 Nov 2004 15:32:39 -0600
List-post: <mailto:towertalk@contesting.com>
FWIW, the AC current on wires 1 and 2 can be measured at the controller with a clamp on ammeter. The nominal normal operating current for that circuit is 3A. When the brake wedge is stuck (or, the solenoid's movement is restricted by any means), the current demand can go as high as 15A.

73

Brad Pioveson, W9FX
FX Rotor Works
www.fxrotorworks.com
----- Original Message ----- From: "David Hachadorian" <K6LL@adelphia.net>
To: "Towertalk Reflector" <towertalk@contesting.com>
Sent: Monday, November 29, 2004 3:15 PM
Subject: Re: [TowerTalk] Why did my Tailtwister stop turning?




----- Original Message ----- From: "Paul Playford" <w8aef@worldnet.att.net>
To: <w2up@mindspring.com>; <towertalk@contesting.com>
Sent: Monday, November 29, 2004 1:46 PM
Subject: RE: [TowerTalk] Why did my Tailtwister stop
turning?



My experience indicates you have a sticking brake
wedge.

If it is a sticking brake wedge, you won't hear the
usual "clank" noise when you stand at the bottom of the
tower and the brake switch is depressed. You will just
hear a fairly loud hum. This is a good way to confirm
this diagnosis the next time the problem occurs. Just
have someone else depress the brake switch while you
are outside listening.

On the capacitor value, it is not critical. The value
Barry mentioned was close enough to work.


Dave Hachadorian, K6LL Yuma, AZ

_______________________________________________

See: http://www.mscomputer.com for "Self Supporting Towers", "Wireless Weather Stations", and lot's more. Call Toll Free, 1-800-333-9041 with any questions and ask for Sherman, W2FLA.

_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk


_______________________________________________


See: http://www.mscomputer.com for "Self Supporting Towers", "Wireless Weather Stations", and lot's more. Call Toll Free, 1-800-333-9041 with any questions and ask for Sherman, W2FLA.

_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>