Pack the conduit with material that is mildew and corrosion resistant. Stuff 
the packing tightlyback about two inches and leave 
a recess at the end of the conduit. Powder the packing surface 
with Sevin dust. (Use to be in a lot of flea powder for dogs) Then
add more packing to opening. Repeat the dusting each spring and fall. Keeps out 
anything 6 or 8 legged critter I have found. Mice
don't seem to like the fiberglass in my conduit. To date no 4, 6, or
8 legged critter problems, especially hornets and wasps. 

Chuck WD4HXG
> 
> From: Eugene Jensen <eugenejensen@nyc.rr.com>
> Date: 2004/11/02 Tue AM 11:17:07 EST
> To: towertalk@contesting.com
> Subject: RE: [TowerTalk] Conduit ends?
> 
> Being a Electrician by trade the easy way is to buy a 1 lb brick of duct
> seal and it just like putty and molds it around the cables and stuff it down
> the conduit. It's cheep quick and very easy to remove when one wants to add
> another cable run. 73 Gene K2QWD
> 
> -----Original Message-----
> From: towertalk-bounces@contesting.com
> [mailto:towertalk-bounces@contesting.com]On Behalf Of Paul Ash
> Sent: Monday, November 01, 2004 8:11 PM
> To: towertalk@contesting.com
> Subject: [TowerTalk] Conduit ends?
> 
> 
> Hello All,
> 
> I have been considering running my coax, antenna
> selector control cable and rotor control cable through a 3"-4"
> inch conduit. I would like to get some opinions on the best
> way to handle the ends that are projecting out of the ground.
> I did read a former thread that talked about two 90 deg bends
> (sounds good for water/rain.) what about bugs/rodents/varmints etc...
> Anyone have a good idea how to seal the ends that would still provide
> passage of the cables and could be removed with a minimum of effort
> whenever it comes time to replace or add to the cables?
> 
> Thanks!
> 
> 73,
> 
> Paul W4QG
> _______________________________________________
> 
> See: http://www.mscomputer.com  for "Self Supporting Towers", "Wireless
> Weather Stations", and lot's more.  Call Toll Free, 1-800-333-9041 with any
> questions and ask for Sherman, W2FLA.
> 
> _______________________________________________
> TowerTalk mailing list
> TowerTalk@contesting.com
> http://lists.contesting.com/mailman/listinfo/towertalk
> 
> 
> _______________________________________________
> 
> See: http://www.mscomputer.com  for "Self Supporting Towers", "Wireless 
> Weather Stations", and lot's more.  Call Toll Free, 1-800-333-9041 with any 
> questions and ask for Sherman, W2FLA.
> 
> _______________________________________________
> TowerTalk mailing list
> TowerTalk@contesting.com
> http://lists.contesting.com/mailman/listinfo/towertalk
> 

_______________________________________________

See: http://www.mscomputer.com  for "Self Supporting Towers", "Wireless Weather 
Stations", and lot's more.  Call Toll Free, 1-800-333-9041 with any questions 
and ask for Sherman, W2FLA.

_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>