Towertalk
[Top] [All Lists]

Re: [TowerTalk] Guy Anchor Corrosion Question 1

To: "David Hachadorian" <K6LL@adelphia.net>,"Towertalk Reflector" <towertalk@contesting.com>
Subject: Re: [TowerTalk] Guy Anchor Corrosion Question 1
From: "Tom Rauch" <w8ji@contesting.com>
Reply-to: Tom Rauch <w8ji@contesting.com>
Date: Thu, 28 Oct 2004 13:46:45 -0400
List-post: <mailto:towertalk@contesting.com>
> Inspecting the failed anchor later, I found that the
> shaft had totally corroded through, with the corroded
> end coming to a pointed shape. The soil here is a top
> layer of clay, then a six inch layer of what the locals
> call "Caliche," and then a deep (at least six feet
> deep) layer of sand. The water level is at six feet.
> The rod failed at the point where it passed through the
> Caliche layer.

Dave,

Were your guy lines insulated? Were they metal and attached
directly between the tower and ground rods?

73 Tom


_______________________________________________

See: http://www.mscomputer.com  for "Self Supporting Towers", "Wireless Weather 
Stations", and lot's more.  Call Toll Free, 1-800-333-9041 with any questions 
and ask for Sherman, W2FLA.

_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk