Towertalk
[Top] [All Lists]

Re: [TowerTalk] Cure for slump in fresh base pour?

To: "Tom Hybiske" <thomas.hybiske@verizon.net>,<towertalk@contesting.com>
Subject: Re: [TowerTalk] Cure for slump in fresh base pour?
From: "FireBrick" <w9ol@billnjudy.com>
Reply-to: FireBrick <w9ol@billnjudy.com>
Date: Mon, 6 Sep 2004 13:30:47 -0500
List-post: <mailto:towertalk@contesting.com>
As a retired licensed Chicago mason contractor I can offer a simple fix.

Steel columns are never set directly onto the concrete piers.
They always leave a small gap.
They fill this gap with a product called Four Star non shrinkable grout.
(that is a local brand name)

It's a fast drying cementicious mix.
I suggest you mix up a small amount, pour it onto the concrete and then place your metal base down with enough pressure to squeeze out the excess. Use a small tool to cut the excess off at the edge of the base with a slight bevel.
Level and let cure.


This prevent water and the accumulation of leaves etc. under the metal base which helps to prevent rust formation.

A bag of grout only costs a few bucks, You will end up throwing the rest away as it will harden once the bag is unsealed.
If you happen to see a construction site where they are setting steel, you may be able to trade a six pack for a gallon of grout.




----- Original Message ----- From: "Tom Hybiske" <thomas.hybiske@verizon.net>
To: <towertalk@contesting.com>
Sent: Monday, September 06, 2004 1:10 PM
Subject: [TowerTalk] Cure for slump in fresh base pour?



I poured a base for a short tower over the weekend. I'm installing a Rohn clone tilt-over base plate. After the pour, a thin sheet of plywood and the base plate was used to align 6 J-bolts in the wet concrete. I guess I must have leaned on the center of the template because after removal of the template, there is a nice 3/16-1/4 in. slump at the middle of the base which collects and holds water. But as hard as I tried to foul this pour up, the base is dead level. Case of luck beats skill I guess. Now I'm afraid of water will collect and freeze under the base plate and cause havoc. Is there skim coat material available that I could trowel on to remove the slump? Should I just leave it as is and not worry about it.


Tom, K3GM
_______________________________________________

See: http://www.mscomputer.com for "Self Supporting Towers", "Wireless Weather Stations", and lot's more. Call Toll Free, 1-800-333-9041 with any questions and ask for Sherman, W2FLA.

_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk


_______________________________________________


See: http://www.mscomputer.com for "Self Supporting Towers", "Wireless Weather Stations", and lot's more. Call Toll Free, 1-800-333-9041 with any questions and ask for Sherman, W2FLA.

_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>