Towertalk
[Top] [All Lists]

[TowerTalk] Transistion from Phillystran to Steel Guys

To: <TowerTalk@contesting.com>
Subject: [TowerTalk] Transistion from Phillystran to Steel Guys
From: "Ron Hylton" <ad7l@hevanet.com>
Date: Sat, 7 Aug 2004 10:59:53 -0700
List-post: <mailto:towertalk@contesting.com>
I'm wondering how most folks make the transition from Phillystran guys to
EHS steel for that last few feet down to the ground.  3 ways come to mind:

1)  Simply interlock (i.e., one inside of the other) the Phillystran thimble
and the steel guy thimble.  This seems like the safest and cheapest way to
go.

2)  Connect the two thimbles with a suitably sized shackle.  This would be
pretty convenient for building or maintenance purposes, but adds another
piece of hardware and another possible failure point.

3)  Use a 502 insulator.  This doesn't seem like a good idea, as it would
add weight, extra "visual profile" to the guy, and an insulator isn't needed
anyway.

In my particular installation, I'm using 1/4 steel, Phillystran HPTG6700I,
and Big Grips.

Any thoughts?

Thanks and 73,

Ron  AD7L
Hillsboro, Oregon

_______________________________________________

See: http://www.mscomputer.com  for "Self Supporting Towers", "Wireless Weather 
Stations", and lot's more.  Call Toll Free, 1-800-333-9041 with any questions 
and ask for Sherman, W2FLA.