To: | TowerTalk <towertalk@contesting.com> |
---|---|
Subject: | [TowerTalk] Tower base holes |
From: | Red <RedHaines@centurytel.net> |
Date: | Fri, 23 Jul 2004 13:22:10 -0500 |
List-post: | <mailto:towertalk@contesting.com> |
I assisted the back hoe operator by digging the first 10" or so by hand,
precisely to the dedired dimension or slightly under, in sod. The back
hoe did not disturb that. The bottom wasn't perfect. I filled it with sufficient limestone screenings and tamped the screenings to produce a solid and level base, on which I placed concrete 'pills' to support the rebar cage and the tower base legs, each 3" from the bottom of the concrete base, to eliminate paths for leaching out the natural alkalinity of the concrete, which protects steel from corrosion. These screenings tamp much easier than many soils. 73 de WOØW _______________________________________________ See: http://www.mscomputer.com for "Self Supporting Towers", "Wireless Weather Stations", and lot's more. Call Toll Free, 1-800-333-9041 with any questions and ask for Sherman, W2FLA. _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | [TowerTalk] Self-supportig tower base size, Red |
---|---|
Next by Date: | RE: [TowerTalk] Aluminum Pipe/Tubing Needed, Kevin Adam |
Previous by Thread: | [TowerTalk] Self-supportig tower base size, Red |
Next by Thread: | [TowerTalk] Engineering PDF for HDX589 / 572, Rich Hallman - N7TR |