Towertalk
[Top] [All Lists]

Re: [TowerTalk] CAT 5 as Rotator cable, sprinkler wire

To: towertalk@contesting.com
Subject: Re: [TowerTalk] CAT 5 as Rotator cable, sprinkler wire
From: KI7WX@aol.com
Date: Fri, 18 Jun 2004 15:34:02 -0400
List-post: <mailto:towertalk@contesting.com>
N0RQ asked about 18ga sprinkler cable for rotors.

I used this wire at my NC station to feed a T2X which was later repalced with 
an M2 Orion. Worked fine on both rotors. I had about a 250-300 foot run and I 
doubled up two conductors for the motor leads. If I'd started with the Orion 
I'd have used 14-3 instead of the sprinkler cable though.

While bopping through Home Despot the other day I noticed they now carry the 
sprinkler cable in 10 x 18ga and the cost is decent.

The small guage cat5 cables worked fine to feed numerous RCS8V boxes. Wire was 
outside for a few years and the jacket on the cat5 was still perfect when we 
took it all down.

Mark
KI7WX/2
_______________________________________________

See: http://www.mscomputer.com  for "Self Supporting Towers", "Wireless Weather 
Stations", and lot's more.  Call Toll Free, 1-800-333-9041 with any questions 
and ask for Sherman, W2FLA.