RG217 is good for rotor loops, rated about 1000W at 144 MHz,
much much more on HF. You can get both N and DIN 7/16 connectors
for it, PL259 (solder type) connectors can also be fitted.  
73 Jim SM2EKM
--------------------------------------------------------------------  
K7LXC@aol.com wrote:
In a message dated 3/1/04 4:35:34 AM Pacific Standard Time, 
Kingsautomotive1@alltel.net writes: 
 
 
   I am installing a beam or two, and have only coax with solid center. 
(Belden 9913, etc.) Has any one used this successfully for the flexing 
  part? 
 
Maybe a large, carefully supported loop? I have heard of using 1/2 " 
corrugated hardline, so maybe it can hold up without breaking where the 
  mast 
 
rotates. I would like to hear of anyone's experience here.
  
 
    No one recommends using 9913 or any solid centered coax where it has to 
move occasionally; i.e. rotation loop. Besides the center conductor moving 
around inside the air dielectric, the solid center conductor will work eventually 
work harden and crack - bad news for any feedline. Terminate the 9913 at the 
top of the tower and use any old stranded center conductor coax to the beam. 
 
Cheers, 
Steve     K7LXC 
TOWER TECH  
 
  
 
_______________________________________________ 
 
See: http://www.mscomputer.com  for "Self Supporting Towers", "Wireless Weather Stations", and lot's more.  Call Toll Free, 1-800-333-9041 with any questions and ask for Sherman, W2FLA. 
 
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk  
 |