If your ground is better than the power companies you are in for some smoke.
A fellow ham nearby put in a great ground, he was also on some low laying
ground
near to a creek. The power company placed its pole on the road allowance, the
road was built up, well above the low laying surrounding field. Guess what,
the
ground in which the pole was planted dried up in the summer, so o o the
grounding
part went right through his system. He just lost some minor stuff but could
have lost
the house if the wiring became very hot.
Chris opr VE7HCB
From: "Glenn Noska" <nazgul34@hotmail.com>
To: towertalk@contesting.com
Date sent: Mon, 19 Jan 2004 20:44:53 -0500
Copies to: nazgul34@hotmail.com
Subject: [TowerTalk] grounding
[ Double-click this line for list subscription options ]
i'm an electrician in the surge capital of the world, Orlando (
did
lightning just hit that house?), Florida. the last three days were
spent devouring old towertalk threads on grounding, super informative!
well, surge protectors are pretty useless without a good ground and
armed with towertalk knowledge i was ready to give my customer's the
best ground their money could buy.
then, a really sharp engineer at Intermatic dropped this little
bombshell. if your ground is a lot better than the utility's ground at
the transformer then all the neighborhood's surges are coming for a
visit. and you might think they're just coming to your ground, but, as
they travel the common they induce surges in the two hots. So, you may
have dodged the big surge, and bought yourself a whole lot of little
ones.
is this significant? do i need to put a big horkin MOV on the
neutral
to the meter that'll add a couple dozen ohms and keep the
neighborhood's surges out? is there such a thing?
all kidding aside, i'm guaranteeing all appliances and
electronics to
$10,000.00 or the homeowner's deductable (installing Intermatic
IG1300-4T-2C). please help.
_________________________________________________________________
Let
the new MSN Premium Internet Software make the most of your high-speed
experience. http://join.msn.com/?pgmarket=en-us&page=byoa/prem&ST=1
_______________________________________________
See: http://www.mscomputer.com for "Self Supporting Towers",
"Wireless Weather Stations", and lot's more. Call Toll Free,
1-800-333-9041 with any questions and ask for Sherman, W2FLA.
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
_______________________________________________
See: http://www.mscomputer.com for "Self Supporting Towers", "Wireless Weather
Stations", and lot's more. Call Toll Free, 1-800-333-9041 with any questions
and ask for Sherman, W2FLA.