| Hi Barry,
OK - thanks for the hint!
Anyway, it looks like the stuff you used was NOT insulated, true?
The wire wire I am talking about is insulated with a PE jacket, 
so that would prevent it from rusting I guess...
Any other comments still very appreciated, tnx
73
Con DF4SA
At 18:45 20.12.2003 +0000, you wrote:
>Avoid stranded copperweld!
>
>A number of years ago, I built a bunch of lowband wires using this 
>stuff (purchased from Wireman).  Within 2-3 years it all broke.  What 
>happens is the strands rub against each other as it sways in the 
>wind, abrades the copper off, exposing the steel core, then it rusts 
>and breaks.  Never again!
>
>Yes, solid copperweld is tough to work with, but I've never had it 
>fail.
>73,
>Barry W2UP
_______________________________________________
See: http://www.mscomputer.com  for "Self Supporting Towers", "Wireless Weather 
Stations", and lot's more.  Call Toll Free, 1-800-333-9041 with any questions 
and ask for Sherman, W2FLA.
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
 |