To: | "Rauh, Michael J (Mike)" <rauh@lucent.com> |
---|---|
Subject: | Re: [TowerTalk] 40m-4 klm |
From: | Don Havlicek <n8de@thepoint.net> |
Reply-to: | n8de@thepoint.net |
Date: | Thu, 16 Oct 2003 22:37:50 -0500 |
List-post: | <mailto:towertalk@contesting.com> |
The reinforcement is at the _middle_ of the boom [at the boom-to-mast
bracket] where there are NO swaged joints, NOT at the joints present
along the boom. Don N8DE Rauh, Michael J (Mike) wrote: Ages ago, K4ISV recommended reinforcing the boom of the KLM 40M4 by inserting a smaller diameter tube inside the boom. Has anyone done this? My 40M4 has swaged boom joints. If I make the insert small enough diameter to pass through the joints, the tube will not be in contact with the inside of the boom, except at the joints. Will this strengthen or stiffen the boom? _______________________________________________ See: http://www.mscomputer.com for "Self Supporting Towers", "Wireless Weather Stations", and lot's more. Call Toll Free, 1-800-333-9041 with any questions and ask for Sherman, W2FLA. _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk |