Go to your local electrical supply house. Burndy makes a variety of
clamps. They are typically brass. Use a thin piece of stainless steel
around the leg of the tower to fix the "mixing of metals" issue. Use a
thin coat of Noalox or Penatrox on everything.

Gerry Smith, W6TER


-----Original Message-----
From: towertalk-bounces@contesting.com
[mailto:towertalk-bounces@contesting.com] On Behalf Of Van Fair
Sent: Tuesday, April 22, 2003 8:45 AM
To: towertalk@contesting.com
Subject: [TowerTalk] Ground for Rohn 25

What is the proper way to attach a #6 ground wire to the leg of a Rohn
25 tower section and where do you get what ever it takes. Pipe clamps I
have found are either coper or galvanized and both will cause a mixing
of metals. Thanks and 73 Van W4GIW