Towertalk
[Top] [All Lists]

[Towertalk] Connectors for CATV hardline

To: <towertalk@contesting.com>
Subject: [Towertalk] Connectors for CATV hardline
From: kq2m@earthlink.net (Robert Shohet)
Date: Fri, 6 Sep 2002 22:20:50 -0400
Depends on the type of cable as well as the size.  My 3/4" CATV was Fused
Disc and the CC was
considerably larger than the PL258 diameter.  It took very vigorous filing
for quite a
long time and then it fit.

Bob KQ2M

----- Original Message -----
From: "Mike Wetzel" <mjwetzel@comcast.net>
To: "Mike Gilmer, N2MG" <n2mg@eham.net>; "towertalk"
<towertalk@contesting.com>
Sent: Friday, September 06, 2002 10:05 PM
Subject: RE: [Towertalk] Connectors for CATV hardline


> Mike,
>
> I just mic'd a pl-259 and got .16" and the center from my 3/4" and got
.175
> so with a little filing and a leather hammer a pl-258 is a nice snug fit.
> Don't have millimeter micrometers.
>
> A lot of mikes here!
>
> Mike W9RE




<Prev in Thread] Current Thread [Next in Thread>