>>>"Frank Davis" said:
> Operators who wish to use the switch in stacked arrays can still do so by app
lying the control voltage to more then one relay at a time leaving all the
others grounded. I have never used the relay in this configuration so can
't vouch for its effectiveness.
This is probably obvious RCS8V, but I wired my stack using position 1=BOT,
2=TOP, 3=BOTH. This was possible by connecting the #3 terminal connection on
the control box to both #1 & #2 through diodes. That allows ports 1 and 2 to
be independent or commonly driven. Port 3 is not used. Works FVB for me even
without matching.
#1 ----------.-----> to relay box #1 terminal
|
#2 -------.--------> to relay box #2 terminal
| |
#3 ---|<--| |
---|<-----|
#4 ----------------> to relay box #4 terminal
#5 ----------------> to relay box #5 terminal
--
73 es God Bless de KK1L...ron rossi(kk1l@arrl.net) <><