Jerry... good idea!  However, tie the three ground rods together and only
run ONE bond to the tower from the ground rods.  Running separate bonds can
cause grounds loops and create a whole new set of problems.

Also, if concrete is going to be poured around your ground clamps... the
lime will eventually cause high resistance joints due to the corrosion.  I
don't recommend "burying" ANY joint in concrete or dirt!  Unless you can
absolutely make a pure hermetic seal!

Paul - K4BET

----- Original Message -----
From: "Jerry Keller" <k3bz@arrl.net>
To: "(Reflector) TowerTalk" <towertalk@contesting.com>
Sent: Thursday, August 01, 2002 11:19 PM
Subject: [Towertalk] Ground Rods


I'll soon be pouring a new tower base, 6 feet deep. I thought I would put an
8-foot ground rod at each corner of the hole, drive them in the remaining 2
feet, tie them all together with #2 solid copper, and run the copper to all
3 of the tower mount J-bolts...then pour concrete around the whole
business... any thoughts?  Jerry K3BZ

_______________________________________________
Self Supporting Towers, Wireless Weather Stations, see web site:
http://www.mscomputer.com
Call 888-333-9041 to place your order, mention you saw this ad and take an
additional 5 percent off
any weather station price.
_______________________________________________
Towertalk mailing list
Towertalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk




<Prev in Thread] Current Thread [Next in Thread>