Towertalk
[Top] [All Lists]

[TowerTalk] Crank up tower climbing safety

To: <towertalk@contesting.com>
Subject: [TowerTalk] Crank up tower climbing safety
From: wy6k@yahoo.com (Michael Watts)
Date: Mon, 4 Feb 2002 20:29:24 -0800 (PST)
A whole of guys have asked me for a description of the nesting 
fixture I use.  So I'll try to describe it here.

I have a TriEx LM470D motorized crankup with positive pulldown.

This is one of those things that's a whole lot easier
to talk about when you can see it.  But I don't think I have any digital
pictures of it.  I think I have some of the prototype, which I made 
out of wood.  That's good enough to illustrate the point - so if I can 
find the pictures I'll scan them in and send them to whoever is 
interested.

The way it works is that each section comes down to rest on it's own 
"platform" which then supports all of that section's weight.  Each 
platform is at the correct height so that all the telescoping sections 
come to rest on their platforms at exactly the same time.  The cable 
winds up being equally slack on both the pull up and pull down 
portions.

Each "platform" is comprised of two beefy aluminum beams mounted 
vertically.  One end of each beam rests on the concrete base and 
the other end points upward.  Each telescoping section comes down and 
rests on top of a pair of such beams.  The beam are held in place by  
connections to the sides of the tower down low, below the point where
the telescoping travel.  So the full length of each pair of beams 
supports the weight of the section that rests on it.  Even if one 
beam were to fail - no tower sections would fall because there is 
another beam still holding that tower section.  Failure of one of 
the beam is highly improbably since there is so little weight on 
it compared to its strength.  The beams are in longitudinal 
compression and can support nearly 100 times the weight of the 
heaviest LM470 telescoping tower section.

Even if you were to cut the cable, it wouldn't matter because 
nothing would move.  It's as safe as climbing a fixed tower at 
that point.

The failure modes would be:  1) failure of two beams - unlikely with 
less than 1000 pounds on something that will support more than 
40000 pounds, or 2) The beams come loose from their mountings and 
fall off to one side.  However, it would be almost impossible for 
this to happen and still have the tower retract seemingly normally.  
And it is next to impossible for it to happen after the tower is 
all the way down and you simply inspect it before climbing.

I only climb the tower when the telescoping sections have been lowered 
onto their "platforms" and I look to make sure they are resting properly 
and the cable is slack.

I apologize for being so poor at describing it.  
I'll try to get some photos together over the next week or so and 
anybody that requests them can have them and it will all make perfect 
sense when you see it.

Michael WY6K


__________________________________________________
Do You Yahoo!?
Send FREE Valentine eCards with Yahoo! Greetings!
http://greetings.yahoo.com

________________________________________________________________________
Where do you get ICE bandpass filters & beverage matching boxes?  The
same place that pays for the hosting of this list:  The eHam Store.