In a message dated 12/19/01 6:43:47 PM Pacific Standard Time, 
W4EF@dellroy.com writes:

> I need to restring a bundle of coax/rotator cables (4 x LMR-400, 3
>  x rotator) across a steel messenger cable suspended between two
>  buildings (~100' span). What is the preferred method for attaching
>  the cables to the messenger. Seems that not all black cable ties are
>  UV stable over the long term. I'd like something with a 15-20 year
>  lifetime. Scotch 35? #14 awg solid copper electrical wire? UV stable
>  tiewrap?

    Put the tie wrap on first and then cover with one or two layers of Scotch 
33 or 88. Should last for years - the tape will keep the UV off of the tie 
wrap.

Cheers,
Steve     K7LXC