Towertalk
[Top] [All Lists]

[TowerTalk] 402 CD Modifications

To: <towertalk@contesting.com>
Subject: [TowerTalk] 402 CD Modifications
From: dick@libelle.com (Dick Flanagan)
Date: Tue, 9 Oct 2001 21:59:18 -0700
At Tue, 09 Oct 2001 19:20:37 -0500, Tim Duffy <k3lr@k3lr.com> wrote:
> Can someone tell me the size and length of the screws used to modify the
> coil connections on the CushCraft 402CD? The modification uses a through
> the insulator screw in place of the stock self tapping screw.  The screw
> size (#6, #8 or #10) is critical so that the screw size matches the wire
> lug at the coil ends. What is the diameter of the coil form?

The complete Leeson 40-2CD modification article is available on-line at
http://www.qsl.net/w6old/402cd.html.  In Page 6 of that article Dave
Leeson wrote:

"I replaced the loading-coil-terminal plated self-tapped screws with
#10-32 x 1-1/4-inch stainless-steel screws. I drilled and tapped holes
through the aluminum tube and secured the screws with safety nuts."

Following these instructions, including the drilling and taping, will
give the desired results.

73, Dick
-- 
Dick Flanagan W6OLD CFII Minden, Nevada DM09db
Visit http://www.cvrc.net/

List Sponsored by AN Wireless:  AN Wireless handles Rohn tower systems,
Trylon Titan towers, coax, hardline and more. Also check out our self
supporting towers up to 100 feet for under $1500!!  http://www.anwireless.com

-----
FAQ on WWW:               http://www.contesting.com/FAQ/towertalk
Submissions:              towertalk@contesting.com
Administrative requests:  towertalk-REQUEST@contesting.com
Problems:                 owner-towertalk@contesting.com