Towertalk
[Top] [All Lists]

[TowerTalk] rohn short section?

To: <towertalk@contesting.com>
Subject: [TowerTalk] rohn short section?
From: k7awb@qwest.net (Stephen Sala)
Date: Sun, 27 May 2001 14:00:15 -0700
>  >  <Is there any reason why a person should use a Rohn 5' base section to
> >  bury in concrete versus using a standard 10' section buried in
concrete?
> >  <Tks, Jerry W5KP

When I put my Rohn 25  85 footer up, I put a 10 foot section in a 5 foot
hole and put another 10 foot section on top of that so I had 15 feet above
the ground before concrete.  That gave me a good long 20 foot length to make
straight before the concrete, using temporary guys  - besides having the
first 10 feet from the bottom of the hole absolutely Rohn straight without
joints.  The tower is no better than the foundation.  I've left two five
foot "towers" in previous locations for the new owners to use as outdoor
patio furniture.

Steve K7AWB