Hey Pete,
My T2X manual says:
Input Voltage.............................120 VAC/ 220 VAC
Motor..........................................24 VAC 2.25 Amp, Capacitor
Start/Run
Brake Selenoid..........................24 VAC, 5.0 Amps
Power Transformer....................120 VAC/ 220 VAC 10% Duty, thermally
protected
Meter Transformer....................120/ 220 VAC/ 13 VAC Continuous Duty
Meter DC voltmeter....................1k ohm/ volts, 1 MA full scale
Meter Scale Direct Reading: North centered, 5
degree
inc.
" " :
South " "
Max. antenna size*.....................20 square feet (1.86 meter squared
Max. effective Moment**.............3400 ft. lb. (470 Kg,M)
Operational Temp Range...........-30 F to +210 F (-34 C to +210 C)
Max. Interconnect cable res....... (Pins 1 & 2 = 0.8 ohm) (Pins 3,4,5,6,7 and 8
=
2.0 ohms
Rotation time..............................45 - 60 seconds with 60 Hz input
Brake..........................................Positive, electrically op wedge
60
seg. @ 6 degrees
Rotor Size................................... 9" (23.7 cm) X 14.04" (35.7 cm)
Recommended mast sizes......... 1 7/8" to 2 1/16" OD (48-53 mm)
* Rotor mounted inside tower
** Effective Moment is defined as antenna turning radius times weight
I can remember about 1 sq.ft wind load to 1.5 sq.ft including the mast (close
for
estimating).
Need any more, let me know glad to help.
73 de n8csp k
--
FAQ on WWW: http://www.contesting.com/towertalkfaq.html
Submissions: towertalk@contesting.com
Administrative requests: towertalk-REQUEST@contesting.com
Problems: owner-towertalk@contesting.com
Search: http://www.contesting.com/km9p/search.htm
|