Towertalk
[Top] [All Lists]

[TowerTalk] HAZER/ROHN guy attach points QUERY

To: <towertalk@contesting.com>
Subject: [TowerTalk] HAZER/ROHN guy attach points QUERY
From: K7LXC@aol.com (K7LXC@aol.com)
Date: Tue, 3 Aug 1999 16:25:09 EDT
In a message dated 99-08-03 16:02:31 EDT, R.Gorski@Astronautics.com writes:

> >Anybody out there got a good design for
>  >"quick-disconnect" guy attach points for a Rohn 25
>  >Hazer?  Glenn-Martin was not much help on this.
>  >
>  >To go past a set of guys, one has to install a
>  >temporary set below the Hazer and then disconnect
>  >the guys.  There must be nothing in the guy point
>  >attachments which protrude and intefer with Hazer.
>  >
>  >
>--In the McMaster-Carr catalog, I see 1) Load-rated spring snaps and 2)
>  Pear-shaped threaded chain connectors. Either may be useful for your
>  application. Farm supply houses as well as larger ACE hdw stores carry
>  these devices. 

      Sure - as long as these devices are RATED for the same minimum breaking 
strength as the rest of the whole guy wire hardware. If in doubt - leave them 
OUT. I doubt that the aforementioned hardware is rated for breaking strength. 

     Look around for some steel carabiners or snaplinks rated at 4000# 
breaking strength if yours is a 3/16" EHS guy system. You local safety supply 
store probably has them. 

Cheers,   Steve   K7LXC
Tower Tech
Champion Radio Products

--
FAQ on WWW:               http://www.contesting.com/towertalkfaq.html
Submissions:              towertalk@contesting.com
Administrative requests:  towertalk-REQUEST@contesting.com
Problems:                 owner-towertalk@contesting.com
Search:                   http://www.contesting.com/km9p/search.htm


<Prev in Thread] Current Thread [Next in Thread>