At 06:29 AM 2/10/99 -0500, L. B. Cebik wrote:
>>
>Mike is exactly right. I failed to note--although the article makes
>clear--that the series matching system using transmission line sections is
>a monoband matching scheme. For triband and other wide band use, ununs
>are preferable.
Except that they introduce several additional connectors into the line,
each of which is a likely failure point. As someone pointed out, you can
always make the 75-50 ohm transition at a convenient half-wavelength point,
and run the rest of the way with 50-ohm coax, so the length issue really
isn't terribly awkward.
73, Pete Smith N4ZR