Larry R. Babb wrote:
>
> The capacitor is an excellant suggestion.
Sorry guys, once the rotor starts to move, the cap is no longer needed.
It's job is to balance out the inductive reactance of the motor coil
windings, during start. After the motor is running, it's nowhere.
And I have yet to see a cap which causes binding in thrust bearing.
Best
Ed
--
FAQ on WWW: http://www.contesting.com/towertalkfaq.html