Towertalk
[Top] [All Lists]

[TowerTalk] US Tower -- Pully Replacement?

To: <towertalk@contesting.com>
Subject: [TowerTalk] US Tower -- Pully Replacement?
From: K7LXC@aol.com (K7LXC@aol.com)
Date: Sat, 31 Jan 1998 18:41:15 EST
In a message dated 98-01-31 18:09:14 EST, lburke@wt.net writes:

> Just got through putting new cables on my US Tower crankup. Also changed out
>  the winch. Now I am beginning to wonder... should I have changed out the
>  pulleys also? 

     Whoops! Yes, the pulleys should be replace as well. That's per the
factory and other knowledgeable persons.

>Do these need lubricating on the inner area where I assume
>  there is a bearing of some kind (taking care to keep oil off the outter
race
>  where the cable comes in contact)?

     The cables and pulleys should be PM'ed every six months. You should do a
visual inspection and then apply a suitable lubricant to the cables and
pulleys. PreLube 6 is such a lubricant. It penetrates the cables as well as
lubricating the pulleys. That way you can use the same material on both. 

     TOWER TECH has PreLube 6 for $21.00 for 2 cans delivered to your QTH. I
have had an on-going series (7 parts!) on towers that includes crank-up
maintenance in my "Up The Tower" column in CQ Contest magazine. You might want
to check it out. 

73,  Steve  K7LXC

--
FAQ on WWW:               http://www.contesting.com/towertalkfaq.html
Submissions:              towertalk@contesting.com
Administrative requests:  towertalk-REQUEST@contesting.com
Problems:                 owner-towertalk@contesting.com
Search:                   http://www.contesting.com/km9p/search

<Prev in Thread] Current Thread [Next in Thread>