At 04:29 PM 11/5/97 -0500, you wrote:
>
>During CQWW my T2X control box suddenly lost direction indication.
>The rotor would still turn, but the meter wouldn't move.
>
>As it turns out, the 1/8 amp fuse on the back of the meter was
>blown.
>
>Any ideas on what might have caused it? Is this just something
>that happens occasionaly?
>
>I replaced the fuse and everything was fine.
>
>73's
>--Lee - KT4ZX
>Georgetown, KY
Lee, check and replace that zener diode in the control box. Same thing
happend to
me and after replacement, it worked beautiful. My zener had a thermal
breakdown
after about 20 to 30 minutes of being turned on. Radio shack sells em' for
about
a buck. Good luck....Steve.....NW9G
--
FAQ on WWW: http://www.contesting.com/towertalkfaq.html