To the notes on possible NEC-4 anomalies with antenna elements having
larger center sections, I have added another note on similar anomalies
with "Close-Spaced Wires" between MININEC and NEC-4. (I am presuming
without detailed checking that this latter possible anomaly would apply
also to NEC-2, since it cannot be by-passed using a correction feature, as
can the stepped diameter element problem.) This possible problem would
have implications for modeling open sleeve couplings, Tee matches, gamma
matches, and other such assemblies in NEC. I hope the note is of use to
someone. URL is below.
-73-
LB, W4RNL
L. B. Cebik, W4RNL /\ /\ * / / / (Off)(423) 974-7215
1434 High Mesa Drive / \/ \/\ ----/\--- (Hm) (423) 938-6335
Knoxville, Tennessee /\ \ \ \ / / || / (FAX)(423) 974-3509
37938-4443 USA / \ \ \ \ || cebik@utk.edu
URL: http://funnelweb.utcc.utk.edu/~cebik/radio.html
--
FAQ on WWW: http://www.contesting.com/towertalkfaq.html
Submissions: towertalk@contesting.com
Administrative requests: towertalk-REQUEST@contesting.com
Problems: owner-towertalk@contesting.com
Search: http://www.contesting.com/km9p/search
|