Hello all,since we have been on the subject of tower loads maybe someone
can help me out. I have a 70ft. rohn 20g tower with guys at the 45 ft level
and a house bracket. the base is set down 5ft deep by 3 by 3 ft and filled
with concrete.Just wondering how much antenna load i could put up and get by
with. seems to me rohn stated 2 sq ft. I am not in a normal high wind area
usually 45 mph is the max .
tks we8w
--