In a message dated 96-09-21 18:19:00 EDT, you write:
>I bought a used 58' Rohn foldover tower thats on the ground waiting
>to be put up. The spec sheet calls for 4 guy anchors 25' out from
>the base spaced 35' apart going up to the hinge point on the tower.
>It also recommends guying at the apex but doesn't say at what
>distance from the base.
>
>1. Would you use the same anchor points (25' out)?
Hi, John --
I'm out of town and don't have my Rohn book so I won't guess at an
answer. I suspect, though, that they should be more at the 80% distance that
is normally recommended. Otherwise the guys would be at a fairly steep
angle. (Note: I could be wrong.)
>2. I dont like climbing towers to do maintainence work so I thought
>the foldover would be a good choice, but I'm having second thoughts
>thinking about this guying and removing it to foldover the tower.
>Is this a nuisance or not?
You should be having second thoughts. Increased mechanical complexity
along with the physical travel of the tower tiltover bits makes it similar to
a crankup -- something's bound to go wrong sometime. And they do. The
stresses on the whole mechanism, backbone, cable, etc. are significant and
can fail. I've rarely seen a backbone section that hasn't bent at some time
or other. There are several iterations of the design that Rohn has come out
with over the years; each time increasing the size and strength of the design
-- you probably don't know which one you've got.
>
>3.Would I be better off just putting up 25G and pretending that
>I like to climb?
IMO, yes. Do a good job of installation and weatherproofing and you
shouldn't have to go back up the tower for awhile. While you can install
everything and have a high degree of confidence in having it last 10 years oe
more with little or no maintenance, you may have a rotator failure in that
time frame.
73 and good luck, Steve K7LXC