                            CABLE ATTENUATION  (dB per 100 ft)
           
             1.8   3.5   7.0  14.0  21.0  28.0  50.0   144   440  1296 

LDF7-50A     .03   .04   .06   .08   .10   .12   .16   .27   0.5   0.9
FHJ-7        .03   .05   .07   .10   .12   .15   .20   .37   0.8   1.7
LDF5-50A     .04   .06   .09   .14   .17   .19   .26   .45   0.8   1.5
FXA78-50J    .06   .08   .13   .17   .23   .27   .39   .77   1.4   2.8
3/4" CATV    .06   .08   .13   .17   .23   .26   .38   .62   1.7   3.0
LDF4-50A     .09   .13   .17   .25   .31   .36   .48   .84   1.4   2.5
RG-17        .10   .13   .18   .27   .34   .40   .50   1.3   2.5   5.0
SLA12-50J    .11   .15   .20   .28   .35   .42   .56   1.0   1.9   3.0
FXA12-50J    .12   .16   .22   .33   .40   .47   .65   1.2   2.1   4.0
FXA38-50J    .16   .23   .31   .45   .53   .64   .85   1.5   2.7   4.9
9913         .16   .23   .31   .45   .53   .64   .92   1.6   2.7   5.0
RG-213       .25   .37   .55   .75  1.0    1.2  1.6    2.8   5.1  10.0
RG-8X        .49   .68  1.0   1.4   1.7    1.9  2.5    4.5   8.4


                            CABLE ATTENUATION (Ft per dB)

             1.8   3.5   7.0  14.0  21.0  28.0  50.0   144   440  1296

LDF7-50A    3333  2500  1666  1250  1000   833   625   370   200   110
FHJ-7       2775  2080  1390  1040   833   667   520   310   165    92
LDF5-50A    2500  1666  1111   714   588   526   385   222   125    67
FXA78-50J   1666  1250   769   588   435   370   256   130    71    36
3/4" CATV   1666  1250   769   588   435   385   275   161    59    33
LDF4-50A    1111   769   588   400   323   266   208   119    71    40
RG-17       1000   769   556   370   294   250   200    77    40    20
SLA12-50J    909   667   500   355   285   235   175   100    53    34
FXA12-50J    834   625   455   300   250   210   150    83    48    25
FXA38-50J    625   435   320   220   190   155   115    67    37    20
9913         625   435   320   220   190   155   110    62    37    20
RG-213       400   270   180   130   100    83    62    36    20    10
RG-8X        204   147   100    71    59    53    40    22    12


             FEET REQUIRED FOR 1 DB ADVANTAGE LDF5-50A VS:

             1.8   3.5   7.0  14.0  21.0  28.0  50.0   144   440  1296

LDF4-50A    2000  1430  1250  910    715   625   435   250   165   100
RG-17       1666  1430  1110  770    560   475   420   120    60    30
FXA12-50J   1250  1000   770  525    435   355   255   120    75    40
9913         835   590   455  320    280   220   150   85     53    29

            
             FEET REQUIRED FOR 1 DB ADVANTAGE LDF4-50A VS:
            
             1.8   3.5   7.0  14.0  21.0  28.0  50.0   144    440  1296
             
RG-17         -     -     -    -     -     -     -     220     90    40
FXA12-50J     -     -   2000  1250  1100  835    625   250    145    65  
9913        1430  1000   715   500   455  345    235   135     75    40
RG-213       910   600   285   200   150  120    85     45     20    13