On 1/24/2020 10:21 AM, Ron AE5E via Topband wrote:
I think a good share of noise on 160 for me is coming in on the power line. The ground
mounted transformer is about 1000' feet away and serves other homes as well as mine. The
lines are all buried. Where it entered the house I would like to try to suppress noise.
I can turn off all lights, appliances, furnace, pumps, etc but the noise is still
significant. If I drop the main breaker it is gone. So that is why it seems
to me it is on the line when it enters the house.
So thinking a 200 amp low pass filer before the breaker box might the a
solution. Maybe it just needs to be bypassed with capacitors, I am only
speculating so far.
So lets hear if from Topband guys who have figured this out!
Ron, AE5E
_________________
I suspect you still have something energized in your
house. Try this: turn the main breaker off and then
hold a pocket AM radio next to the energized mains
listening for noise and then compare to the "de-energized"
lines in your house. I am thinking you will hear
no noise in either case. If your theory was correct,
you would hear noise on the mains coming in and
nothing on the house wiring.
In any event, a 200A RFI filter is a non-starter.
If the noise is somehow on the mains coming in, you
need to move your antenna away from your house wiring.
Possibly listen on a loop antenna that you can locate
in a corner of your yard, and then orient it to null
the remaining noise.
Rick N6RK