Re: Topband: Any way to check isolation transformer for FCP

To: topband@contesting.com
Subject: Re: Topband: Any way to check isolation transformer for FCP
From: Andy - YL2QN <yl2qn.andy@gmail.com>
Date: Mon, 18 Jan 2016 11:52:00 +0200
List-post: <topband@contesting.com">mailto:topband@contesting.com>
Guido,

>>> It sounds strange, because to have 45,6 uH with 20 turns the Al should be
1140.

Thanks a lot. Sure I was wrong with inductance.
For 20 turns:
T-300A-2 AL=228, L=9.12uH
T-300-2   AL=114, L=4.56uH

To get same inductance on T-300-2 need to have 28T. But coupling will
between primary and secondary will be changed. How much it critical ?

Regards,
Andy - YL2QN
_________________