BTW. Carl
I agree completely with Tom that there's no point in having a static-bleed
choke on a grounded shunt fed tower!
73,
Charlie, K4OTV
-----Original Message-----
From: Topband [mailto:topband-bounces@contesting.com] On Behalf Of Tom W8JI
Sent: Friday, February 21, 2014 8:02 PM
To: Carl Braun; '160'
Subject: Re: Topband: Shunt feeding the Skyneedle - new developments
Since then I've moved the variable capacitor inside the panel and mounted it
to a ¾" think Plexiglas sheet mounted to the back plane with nylon bolts and
washers. There is a 1" air gap between the Plexiglas and the backplane. I
now have seen the 42+j0 ohms change to 45 - j11 ohms...that's the lowest
reactance I can tune the capacitor for. Not really sure if its +j11 ohms or
- j11 ohms but I assume if the reading was + j11 I could continue to tune it
out with the capacitor but I cant.
Does the capacitor not play well with a steel enclosure?>>>>
Any enclosure will change things, especially a metallic enclosure. Just
readjust the cap.
<<<<The other strange situation I'm experiencing is when I connect my Array
Solutions static bleed choke to the feed thru insulator at the outside of
the panel to ground the resonant frequency jumps to 2.014 MHz at 25 +j0
ohms...remove it entirely and I'm back to my 45 - j11 ohms.>>>
The choke is completely unnecessary with a shunt feed tower. It won't help a
thing, so leave it out.
73 Tom