Gentlemen: Here is Force-12 beam as top hat info for any needing it.
Thanks Natan for quick response. Force-12, you're the greatest!
73, Doug NX4D
----- Original Message -----
From: force12e
To: 'Doug Waller'=20
Sent: Thursday, August 09, 2001 1:17 PM
Subject: RE: Grounding of beam elements
Hi Doug,
You can ground all the elements except for the drivers with minimal =
affect on the array. As the PVC used is not designed to withstand the =
high voltage possible, since the array will be at the end of the =
monopole, I would recommend an additional layer of insulating tape =
between the PVC and the aluminum. This precaution is only suggested if =
you plan on using 1500 watts or more.
Regards,
Natan W6XR
--