Paul,
I think you need to use the Icom Civ for rig control.
The IC-745 sticks in my mind as the rig to use.
N4PY has software you can use for it.
I am in the process of getting my Omni V set up for rig control.
Here is what Carl (N4PY) told ne to use for the Omni V:
CIV Address 1Eh
1200 baud rate
Radio type IC-GEN
Select the correct comport
Your serial cable must have just 3 wires in it. I made a cable
with a male DB 25 that plugs into the Omni V and a female DB 9
on the other end that plugs into the PC serial port. The
cable is 2 RG/174 cables. The first cable has the center lead
going to pin 2 on the DB 25 and pin 2 on the DB 9. The second
cable has the center lead going to pin 3 on the DB 25 and pin 3
on the DB 9. The shields on both cables are connected together
and go to pin 7 on the DB 25 and pin 5 on the DB 9.
I am making up my cable today using a 5 conductor with shield.
--
73,
Don, NN8B
"Meanwhile, with ever increasing power, the telegraph has become not only
the master of commerce, but the tongue of mankind." - James D. Reid, 1886