Thanks Mike

Regards
  Mike K1PEV 

Sent from my iPhone

> On Jan 11, 2020, at 11:27 PM, Mike Bryce <prosolar@sssnet.com> wrote:
> 
> The EEEEEE on the display indicate a fault in the counter. Most likely  RF 
> 
> The display is nothing more than a frequent counter 
> 
> There is no out of band error in that radio
> 
> Mike wb8vge 
> 
> Sent from my iPad
> 
> Knowledge is knowing a tomato is a fruit; Wisdom is not putting it in a fruit 
> salad.
> 
> 
>> On Jan 11, 2020, at 9:38 PM, Ken Brown <kenradiobrown@gmail.com> wrote:
>> 
>>  Two major differences between receive and transmit are current consumption
>> and RF production. Since he is a new ham his power supply and connections,
>> station grounding and antenna system may have problems he has not yet
>> learned how to avoid and repair. To determine if it is either one of those
>> two differences, current draw or RF, but not which one, have him transmit
>> with with the TX power turned all the way down and see if the problem goes
>> away. Once that is confirmed, have him transmit into a good 50 Ohm
>> termination (dummy load) using a known good cable and properly tightened
>> connectors, and the TX power back at normal setting.Then if the problem is
>> still there, turn the power down to minimum and see if it goes away. With
>> that information you should be able to figure out if it is the increased
>> current draw of transmit, or the production of RF that is causing the
>> problem.
>> 
>> I'm not real familiar with the Omni C, but perhaps If someone tries to
>> transmit out of band it will show EEEEE.
>> 
>> DE N6KB
>> 
>>> On Sat, Jan 11, 2020 at 2:51 AM Silevitch, Michael <
>>> m.silevitch@northeastern.edu> wrote:
>>> 
>>> I loaned my OMNI C to a new ham. When he tries to transmit the display
>>> shows all Es and there is clearly something wrong. The unit was fine when
>>> it was loaned out. The unit is fine on receive. I don’t have the unit back
>>> yet so cannot troubleshoot.
>>> 
>>> Any wisdom would be appreciated.
>>> 
>>> Regards
>>> Michael K1PEV
>>> 
>>> Sent from my iPhone
>>> _______________________________________________
>>> TenTec mailing list
>>> TenTec@contesting.com
>>> https://nam05.safelinks.protection.outlook.com/?url=http%3A%2F%2Flists.contesting.com%2Fmailman%2Flistinfo%2Ftentec&amp;data=02%7C01%7Cm.silevitch%40northeastern.edu%7Ca71906a069cd4d65d66908d79717a906%7Ca8eec281aaa34daeac9b9a398b9215e7%7C0%7C0%7C637144000198780574&amp;sdata=sanr1Q9OPP6AH%2BBNZDfBP0ooVubF33yGPlDcsnTSa4I%3D&amp;reserved=0
>>> 
>> _______________________________________________
>> TenTec mailing list
>> TenTec@contesting.com
>> https://nam05.safelinks.protection.outlook.com/?url=http%3A%2F%2Flists.contesting.com%2Fmailman%2Flistinfo%2Ftentec&amp;data=02%7C01%7Cm.silevitch%40northeastern.edu%7Ca71906a069cd4d65d66908d79717a906%7Ca8eec281aaa34daeac9b9a398b9215e7%7C0%7C0%7C637144000198790535&amp;sdata=EPi3MF8OPtzvUbAXnbE8exr8iBhYkNBur9m3WDo4Buc%3D&amp;reserved=0
> _______________________________________________
> TenTec mailing list
> TenTec@contesting.com
> https://nam05.safelinks.protection.outlook.com/?url=http%3A%2F%2Flists.contesting.com%2Fmailman%2Flistinfo%2Ftentec&amp;data=02%7C01%7Cm.silevitch%40northeastern.edu%7Ca71906a069cd4d65d66908d79717a906%7Ca8eec281aaa34daeac9b9a398b9215e7%7C0%7C0%7C637144000198790535&amp;sdata=EPi3MF8OPtzvUbAXnbE8exr8iBhYkNBur9m3WDo4Buc%3D&amp;reserved=0
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec
<Prev in Thread] Current Thread [Next in Thread>